San diego municipal code chapter 14 article 2.
City of los angeles standard retaining wall detail.
Lap all steel 16.
Design of retaining walls as presented in this bulletin are in accordance with sections 1610 1 and 1807 2 of the city of los angeles building code labc.
Retaining or slough wall 4 foot high or less 178 kb view.
Acceptable engineering criteria for retaining wall design.
1149 s broadway suite b 10 los angeles ca 90015 phone.
Plumbing plan check correction list for 2017 codes 422 kb view.
Metal bin type retaining wall.
City of los angeles electrical plan check correction list.
Concrete block units to be standard 8 x8 x16 units conforming to ubc standard 21 4.
6 concrete block masonry wall detail 6 0 height maximum general specifications.
Multiple cover details for sanitary sewer manholes.
If any information on any of the standard plans is not legible it is the user s responsibility to obtain a legible copy from the bureau of engineering vault located at.
Concrete block units to be staggered running bond.
Concrete mix for footing to be 1 part cement to 2 5 parts sand to 3 5 parts gravel with a maximum of 7 5 gallons of water per sack of cement minimum f c 2 500 psi.
The standard plans are divided into several series.
Concrete block retaining wall h 6 0 max b3761 1 b3761 2.
Back to standard plans main index.
Residential code section r404 4 specifies that retaining walls shall be designed to ensure.
Retaining walls heights are also regulated by the zoning laws of the city as follows.
Page 1 of 2 retaining or slough wall 4 0 high or less.
Each series contains several standard plans.
Alternative design procedures justified in a geotechnical report may also be approved.
City of los angeles electrical plan check correction list.
Concrete block units to have vertical continuity of the cells unobstructed.
Disabled access standard details notes for commercial buildings.
As a covered entity under title ii of the americans with disabilities act the city of los angeles does not discriminate on the basis of disability and upon request will provide reasonable accommodation to ensure equal access to its programs services and activities.
Soil lateral loads labc 1610 1 general.
213 847 0700.
Build safe well and fast with the city of los angeles department of building and safety.
Concrete block units shall conform to astm c90.
County of los angeles department of public works building and safety division based on the 2011 lacrc 1014 r404 4 article 1 10 25 12 page 1 of 7 design of retaining walls issue.