O 03 2010 1 exh.
Concrete valley gutter and minimum slope.
3 2 valley gutters 1.
Maximum grades on curb and gutter and streets shall be 10 percent.
Contraction joints adjacent to concrete pavement on tangents and flat curves are to match the pavement joints with intermediate joints not to exceed 10 centers.
The objective of urban storm drainage is to provide safe passage of vehicle traffic by collecting stormwater from the roadway and to convey it safely to an adequate receiving body while preventing damage to adjacent private properties or undue risk to pedestrian traffic during the design storm event.
Calculate the gutter slope by dividing the length of the gutter needed by 10.
For curb gutter and curb gutter provide contraction joints at 10 centers max.
A minimum slope along any curb and gutter shall be 0 7 percent and on cross gutter shall be one half percent.
For slate this will be at 25 for machine made tiles it will be 35.
Valley gutters crossing local street intersections with local or collector streets shall be a minimum of six feet wide.
O 13 2015 1 exh.
To 3 8 9.
Form saw or score 1.
Table 8 of e2 as1 quotes the maximum catchment area for the two commonly used valley gutter widths 160 mm for metal tiles and 250 mm for metal cladding and concrete tiles to be only 16m2 and 25 m2 respectively regardless of roof cladding type or pitch or gutter profile.
Width contraction joints min.
Section 441 miscellaneous concrete 441 1 general description this work includes placing portland cement concrete as follows.
The minimal slope needed for proper gutter drainage is 1 25 cm 1 4 inch for every 3 metres 10 feet of gutter.
The pitch of a pitched roof is determined by the construction material of the covering.
Concrete valley gutters shall be constructed per mag detail 240.
All pedestrian facilities will conform to the current federal ada.
Water falls towards a parapet gutter a valley gutter or an eaves gutter.
Seal the joints with hot poured elastic 8 max.
Curb gutter and curb gutter expansion joints shall be located in accordance with section.
If the length of the gutter is 10 5 metres 35 feet the amount of slope required is 1 25 cm 1 4 inch multiplied by 1 metres 3 5 feet which when.
Type joint sealer section 826 02a 2 of the standard specifications include all a minimum 2 depth at approx 10 intervals.
As slope paving on end rolls cut slopes paved ditches spillways and ditch slopes in median pavement as sidewalks in concrete curbs gutters curb and gutters and valley gutters as nonreinforced headwalls.